Dank u wel voor uw aanvraag. We have sent the requested file to your email address.
Our apologies. Unfortunately, something went wrong while sending the file.
Our apologies. You have been detected as a robot. Try again.
Accessories

Priming chambers

Priming chambers add a self-priming feature to a standard horizontal pump. A centrifugal pump by its principle is not self-priming, because of its limited ability to transport air. The priming chamber is initially filled with solution. The priming time depends on length/diameter of suction pipe. After the initial filling of the chamber, next time, the pump will automatically reprime. The maximum pump flowrate will be reduced by approximately 20%, compared to the published flow curve. The pressure/head will not be affected.

Discover the benefits of our priming chambers. 

Request a quote
Back